‘REVA’   DRY HEAT STERILISER        (G.M.P. MODEL)   


MACHINERY FOR INJECTABLE SECTION
(Automatic Line) 
  

Working Space in mm Cubbic Feet Heating Load (kw).
900 x 900 x 1200 ht. 36 24   One
900 x 1200 x 1200 ht.  48  30   One
1200 x 1200 x 1200 ht. 64 36   One
1200 x 1200 x 1500 ht.  80 48   One

Price for Extra Trolley  One 

Extra Price for Cooling Coils  One                                         

HEATING CYCLE
The ampoules ‘Vials’ bottles  placed in trays are washed in non-sterile room and loaded on the trolley.
The trolley is moved to the sterilizer on a transfer trolley. Temperature and Times are set on the Digital Controller. The Impeller mounted on the top circulates the hot air horizontally over the charge. The air is heated by elements  mounted on the top. Fresh air enters the system through Hepa Filter Module.
The system incorporates two doors, one opening into the sterile room and the other opening in the non-sterile room. Both the doors are pneumatically interlocked. The temperature profile during sterilization cycle is recorded on a circular chart recorder,validation of the system is provided by a six-point digital temperature scanner.  

COOLING CYCLE 
After the time period required for sterilizing the batch has elapsed, the heating circuit shuts of. The pneumatics damper (exhaust ) opens and  and cooling operation commences.

TECHNICAL SPECIFICATIONS

Temperature Upto 300ºC.
Insulation 125mm (t) Mineral Wool.
Air recirculation A 2 H.P. 1440-RPM motor drives the impeller. Air enters the Chamber through perforations provided  passes   horizontally over the charge and is recirculated.
Heating Coil type elements are mounted on the top. Parallely placed and at right angle to the flow of air from the impeller. All eclectrical connections can be serviced from the top.
Doors Two Doors, one opening into the sterile room and the other into the Non-sterile room. The doors are lined with silicon rubber for sealing. The door in the sterile room is claded with S.S. 304 sheet.
Interlocking To maintain the barrier between the sterile and non-sterile room, both the doors are pneumatically interlocked. The pneumatic system  consists of pneumatic Cylinders, solenoid valves and flow control valves.
Material of Construction Interiors with 14 gauge S.S. 316 quality sheets. Exteriors with 14 gauge S.S. 304 Quality sheet.frame work of Rolled steel sections 6, 5 & 3mm. th. interior frame work of S.S 316 qlty. 
Trolley Fabricated from S.S. 316 Quality angles & flats with  ‘U’-  Groved Stainless Steel wheels.
Transfer trolley Fabricated from S.S. 304 Quality Angles & flats with castor wheel for sterile & Non-sterile room.
Hepa Filter Module Air entering the system is passed through a Hepa FilterModule  consisting of a pre-filter up to 5 microns, a blower & a Hepa Filter up to 0.3 microns. The filtered air is fed to the impeller for circulating in the system.
Temperature Control & Timer A combined Electronic Digital Controller  & Timer is  installed. ±2ºC., one probe centrally mounted
Scanner A six point Digital Scanner is incorporated, with facility of Hold &  Scan at all six points.
Temperature Recorder A, 1 point Circular Chart recorder is installed with chart Dia 8”.
Exhaust damper Controlled by solenoid valve  and is opened during the initial heatup, shuts off and re-opens during cooling cycle.
Cooling Coils Crimped Finned Tubes with headers, S.S. 304 Quality tospeed up cooling cycle.
Panel Board Consists of : Ammeters, Voltmeter, Voltmeter switch, HRC fuses & Circular chart Recorder.
Control panel Motor Starter, Contactors, Rotary Switches, Indicating lights (contd,) for heating & Cooling cycle and phase indicating lights.
Finish All stainless steel components will be buffed to matt finish.  
Guarantee All ‘REVA’ Equipments are guaranteed for a period of one year for perfect material & workmanship.